Inspection report — 12 Larkspur Road.pdfReportCMP-2841J. Patel2.4 MB01 Jun 2026
EICR 2024 — 44 Stoneleigh Ave.pdfCertificatePRT-09387Halton Property Services812 KB30 May 2026
Ceiling damage — photoset 14 images.zipPhotoCMP-2841Resident upload18.2 MB29 May 2026
Awaab quarterly board pack.pdfReportS. Whitmore6.1 MB28 May 2026
Resident complaint transcript.docxCommunicationCMP-2840Contact Centre92 KB27 May 2026
Gas Safety CP12 batch 04-26.pdfCertificateNorthern Gas11.4 MB26 May 2026
Pre-works photos — Block C.jpgPhotoCMP-2820Halton Property Services4.7 MB24 May 2026
Asbestos R&D survey 2022.pdfCertificatePRT-09823Sentinel Surveys3.3 MB21 May 2026

DampSurvey-Pro Investigation Evidence

Specialist damp, mould & timber investigation engine — feeding evidence into the compliance control centre

Integration · LiveReport Complete
DampSurvey-Pro· Specialist Investigation Platform

Hub raises the request → DampSurvey-Pro conducts the survey → evidence, hazards & recommendations return to Housing Compliance Hub.

Investigation Status
Linked case CMP-2841
  1. Requested
  2. Assigned
  3. In Progress
  4. Report Complete
  5. Actions Raised
Damp & Mould Specialist Investigation Report

DSP-INV-48211

Property
12 Larkspur Road, Flat 4B · Manchester M14 7QJ
Surveyor
Jaya Patel MCIOB · Sentinel Damp Specialists Ltd
Inspection date
01 Jun 2026
Report generated
02 Jun 2026 · 14:32
Risk rating
High
Moisture source
Combined: defective extractor fan + suspected external rainwater ingress
Rooms affected
Kitchen ceiling · Bathroom external wall · Bedroom 2 reveal
Photos attached
42 images
Awaab compliance
Cat 1
Social housing mode
Enabled · Awaab-aligned reporting
Hazards Identified
  • HHSRS Cat 1 — Damp & Mould Growth
  • Aspergillus colonisation on plasterboard
  • Cold bridging at concrete wall junction
Environmental Readings Summary
Kitchen RH
78% RH
Bathroom RH
84% RH
Bedroom RH
62% RH
Surface temp (wall)
11.4 °C
Protimeter (ceiling)
WME 28%
CO₂ avg
1,420 ppm
Recommendations Raised (6)
  1. 01Replace defective bathroom extractor fan (15 l/s continuous)
  2. 02Investigate external rainwater goods to flat above
  3. 03Specialist mould remediation — kitchen ceiling & bathroom wall
  4. 04Improve trickle ventilation provision to bedrooms
  5. 05Schedule 6-week follow-up moisture monitoring
  6. 06Issue resident with damp & mould advice pack