Case Management
342 open cases · 14 overdue · average resolution 11.4 days
Damp ingress — kitchen ceiling
Opened 28 May 2026 by Resident Services · Compliance Officer: Sarah Whitmore
Property Information
- Address
- 12 Larkspur Road, Flat 4B
- UPRN
- 100022611743
- Property type
- 2-bed mid-floor flat (1962)
- Tenant
- Adetola Akintola · since 2019
- Vulnerabilities
- Asthma (child, age 7)
- Region
- Manchester · M14
- Last inspection
- 12 Mar 2026
Compliance Status
- Gas Safety (CP12)Valid · Sep 2026
- EICRValid · 2028
- EPCBand C · 2031
- Asbestos Survey2022 R&D
- Awaab CategoryCat 1 — Damp & Mould
- Fire Risk AssessmentBlock FRA 2025
Timeline
Full case chronology
Resident reported damp on kitchen ceiling
28 May 2026 · 09:14 · Channel: phone
Case triaged as Awaab Category 1
28 May 2026 · 09:42 · Compliance Officer S. Whitmore
Inspection scheduled with J. Patel
29 May 2026 · 14:00 · SLA-compliant
Inspection report drafted
01 Jun 2026 · Awaiting sign-off
Actions
Assigned, in-flight and overdue
Survey kitchen ceiling cavity
J. Patel · Internal
Due 04 JunIn ProgressIssue dehumidifier to resident
Northern Maintenance Ltd
Due 05 JunScheduledRemedial works — strip & replace plasterboard
Halton Property Services
Due 11 JunAwaiting QuotePost-works inspection & sign-off
S. Whitmore
Due 14 JunScheduled
DampSurvey-Pro Investigation Evidence
Specialist damp, mould & timber investigation engine — feeding evidence into the compliance control centre
Hub raises the request → DampSurvey-Pro conducts the survey → evidence, hazards & recommendations return to Housing Compliance Hub.
- Requested
- Assigned
- In Progress
- Report Complete
- Actions Raised
DSP-INV-48211
- Property
- 12 Larkspur Road, Flat 4B · Manchester M14 7QJ
- Surveyor
- Jaya Patel MCIOB · Sentinel Damp Specialists Ltd
- Inspection date
- 01 Jun 2026
- Report generated
- 02 Jun 2026 · 14:32
- Risk rating
- High
- Moisture source
- Combined: defective extractor fan + suspected external rainwater ingress
- Rooms affected
- Kitchen ceiling · Bathroom external wall · Bedroom 2 reveal
- Photos attached
- 42 images
- Awaab compliance
- Cat 1
- Social housing mode
- Enabled · Awaab-aligned reporting
- HHSRS Cat 1 — Damp & Mould Growth
- Aspergillus colonisation on plasterboard
- Cold bridging at concrete wall junction
- 01Replace defective bathroom extractor fan (15 l/s continuous)
- 02Investigate external rainwater goods to flat above
- 03Specialist mould remediation — kitchen ceiling & bathroom wall
- 04Improve trickle ventilation provision to bedrooms
- 05Schedule 6-week follow-up moisture monitoring
- 06Issue resident with damp & mould advice pack
DampSurvey-Pro provides specialist damp, mould and timber investigation evidence. Housing Compliance Hub manages risk, deadlines, actions, evidence and compliance oversight — DampSurvey-Pro remains the investigation engine.
Evidence
12 items · uploaded by 4 contributors
Inspection report.pdf
Report
Ceiling photo 01.jpg
Photo
Ceiling photo 02.jpg
Photo
Moisture reading.csv
Data
EICR 2024.pdf
Certificate
Resident statement.docx
Communication
Contractor quote.pdf
Quote
Pre-works photo.jpg
Photo